Skip to main content

Standard Optical Pick-up

The Optical Pick-Up unit is designed to be temporarily fitted for aircraft testing purposes.  

Description

The Optical Pick-Up unit is used to produce a speed reference signal from a rotating component for timing and indexing purposes. OPU’s have an operating range of up to 2 meters and can be used to simplify installation when the use of an MPU is not practical or safe. Helitune OPU’s have been specifically designed for aircraft installations and are ideally suited for use on helicopter tail rotors and high-speed transmission shafts.

The Optical Pick-Up unit works by transmitting a beam of infra red light, which is reflected back to the unit by the passing of a target of reflective tape or paint attached to the rotating component. An electrical pulse is produced each time the target comes into view and the red LED indicator illuminates the OPU body. This signal is used to generate a speed output and a timing reference for balance data, vibration signatures, and tracking information.

Product Specification

Sensing Speed Range

3 to 50,000 rpm (subject to min.target passing period of 50μs)

Sensing Distance20 to 1000 mm for reflective tape with 25x25 mm target 75 to 200 mm for reflective paint  with 25x25 mm target
Timing resolution

0.25º (<6000 rpm), 7µs (<6000 rpm), @ 120 mm with reflective paint

MTBF38,000 hours
Operating Temperature Range  -40º C to +70º C
IndicatorsRed lamp in presence of target

EMC

RTCA/DO-160G

Electrical Specification

 
Connector

MIL-DTL-26482 (Example mating connector: 62GB-51T08-04S)

Electrical InterfaceOne TTL compatible output. (Max sink/source current 10mA)
Power Supply+10 to +30V DC, at 100mA max. Reverse polarity protection
Isolation10M ohm @ 100V (case to electronics)

Physical Specification

 
Size56mm (Including stud) x 48 mm (excluding mating connector) x 25 mm
Weight83 grams, including 2 locking nuts
Fixing16 mm long stud concentric with the sensing elements with 5/8 UNF thread
SealingDIN 40 050 IP65
Helitune Part Number007923

 