1mV/N Sensitivity, BNC Connector, 5000N pk Measurement Range
Sensitivity (±10%): 1mV/N
Measurement Range: 5000N pk
Resolution: 100mN RMS
Head Weight: 120g
Total Weight: 200g

1mV/N Sensitivity, BNC Connector, 5000N pk Measurement Range
Sensitivity (±10%): 1mV/N
Measurement Range: 5000N pk
Resolution: 100mN RMS
Head Weight: 120g
Total Weight: 200g

1mV/N Sensitivity, BNC Connector, 50000N pk Measurement Range
Sensitivity (±10%): 0.1mV/N
Measurement Range: 50000N pk
Resolution: 1000mN RMS
Head Weight: 1000g
Total Weight: 2kg

25mV/N Sensitivity, BNC Connector, 200N pk Measurement Range

2.5mV/N Sensitivity, BNC Connector, 2000N pk Measurement Range
Sensitivity (±10%): 2.5mV/N
Measurement Range: 2000N pk
Resolution: 50mN RMS
Head Weight: 80 grams
Total Weight: 160 grams

IEPE, Integrated Cable to 3x BNCs
Sensitivity (±10%): 2 options, 10mV/g and 100mV/g
Max Frequency Range: 1Hz to 500Hz
Case Material: SBR Rubber, 82 Shore A
Weight: <0.7kg

100mV/N Sensitivity, M5 Connector, 50N pk Measurement Range
Sensitivity (±10%): 100mV/N
Measurement Range: 50N pk
Resolution: 2mN RMS
Head Weight: 15 grams
Total Weight: 20 grams

Battery Powered Single Channel IEPE Signal Conditioning Unit

Combined Charge and IEPE Signal Conditioner/Amplifier


The 8401 IEPE Sensor Simulator provides a simple and reliable method for verifying signal conditioning systems without requiring a connected accelerometer. Installed in place of an IEPE sensor, the unit accepts input from a voltage function generator to simulate sensor output signals.
Powered directly from the IEPE signal conditioning supply, the simulator enables engineers to confirm system configuration, check cable integrity and validate measurement chains before testing begins.
Ideal for troubleshooting, commissioning and laboratory setup, the 8401 helps ensure accurate measurement performance across vibration test systems.

The VC-01 Handheld Calibrator provides a fast and practical method for checking accelerometer response at a known fixed frequency and vibration level. Designed for both field and laboratory environments, it enables engineers to confirm sensor performance before or during testing.
With simple one-button operation, the test accelerometer can be mounted directly onto the calibrator using the supplied stud adaptor or adhesive mounting methods such as petrowax. The generated reference signal can then be monitored using a signal analyser or oscilloscope and compared against the known excitation level.
Compact, lightweight and battery powered, the VC-01 offers a convenient solution for routine sensor verification and on-site measurement confidence.

Combined Charge and IEPE Signal Conditioner/Amplifier

Charge Output, Top Entry M3.5 Microdot Connector, Ceramic Isolated Adhesive Mount

IEPE, Top Entry 10-32 Microdot Connector, Ceramic Isolated Adhesive Mount

IEPE, Top Entry 10-32 Microdot Connector, Adhesive Mount